DC Energy Storage Systems

Data Center Emergency Cooling Study

Active Power recently commissioned Opengate Data Systems, a Massachusetts based engineering firm to examine the impact of a power outage in a data center environment and the subsequent loss of cooling. In the event of a power disruption, the ambient temperature can rapidly increase since a power outage will usually force the data center’s cooling system to shutdown. It typically takes two to three minutes before full cooling capacity is restored and all cooling systems cycle back on. Active Power’s CoolAir technology was also reviewed for its performance during power disruptions and its ability to solve these thermal overload conditions. To access the full study, click here.

TACAS Technology

The CoolAir DC stores energy in the form of compressed air and heat. During a utility outage, the compressed air is routed through a Thermal Storage Unit (TSU) to acquire heat energy. The heated air spins a simple turbine/alternator to produce electric power. The CoolAir DC also contains a small, continuous-duty flywheel to support the critical load during the brief period required for the turbine to spin up to speed.

more...

Product Data Sheets

CleanSource UPS

Multi-Module Systems Overview

Multi-Module Systems E-Frame

Multi-Module Systems Z-Frame

Single-Module Systems

DC Solutions

CleanSource DC Energy Storage

Complete Systems + Components

PowerHouse Continuous Power System

GenStart

UL Listed   CE

CleanSource DC & CoolAir DC

The Only Energy Storage System and UPS that Provides Simultaneous Backup Power and Cooling

CoolAir solutions, based on Active Power’s revolutionary Thermal & Compressed Air Energy Storage (TACAS) technology, provide an extended runtime battery-free energy storage solution for 3-phase Uninterruptible Power Supply (UPS) applications. CoolAir represents the only minute-for-minute alternative to lead-acid batteries for all critical operations with none of the inherent problems typically associated with batteries.

High Availability

  • Highly Reliable Energy Storage
  • Redundant Parallel Architecture
  • Consistent and accurate runtime
  • Scalability of power and runtime

Peace of Mind

  • 20-Year Lifespan
  • Low Maintenance for entire solution
  • Up to 10 years full warranty
  • Built-in monitoring (including energy storage)
  • Fixed annual costs

Flexibility

  • Integrated internal manual maintenance bypass
  • 0° to 40° C operating temperature range (including energy storage)
  • Open architecture
  • Top/Bottom Entry

Thermal Overload Mitigation

  • Provides cooling during discharge
 

Green Solution

  • Battery-free energy storage